Technical specifications

Model 1

Physical Specification

Dimensions: 336 mm x 330 mm x 345 mm

(L x W x H): 664 mm x 600 mm x 1370 mm (with trolley)

Weight: Approximately 9.5 kg,

Approximately 31.0 kg (with trolley)

Screen

Display Size: 12.1 Color active matrix TFT touch

Display Resolution (H) x (V): 1280 x 800 pixels

Brightness: Adjustable

Ventilation Specifications

Patient Type: Adult, Pediatric, Neonate Invasive

Ventilation Mode:

VCV (Volume Control Ventilation)

PCV (Pressure Control Ventilation)

VSIMV (Volume Synchronized Intermittent Mandatory Ventilation)

PSIMV (Pressure Synchronized Intermittent Mandatory Ventilation)

CPAP/PSV (Continuous Positive Airway Pressure/ Pressure Support Ventilation)

PRVC (Pressure Regulated Volume Control) V + SIMV (PRVC + SIMV)

BPAP (Bilevel Positive Airway Pressure) APRV (Airway Pressure Release Ventilation) Apnea Ventilation

Non-invasive Ventilation Mode:

PCV (Pressure Control Ventilation)

PSIMV (Pressure Synchronized Intermittent Mandatory Ventilation)

CPAP/PSV (Continuous Positive Airway Pressure/Pressure Support Ventilation) BPAP (Bilevel Positive Airway Pressure) APRV (Airway Pressure Release Ventilation)

Controlled Parameters

O2%: 21-100% (increments of 1%)

VT (Tidal Volume): Adult: 100-2000 mL (increments of 10 mL) / Pediatric: 20-300 mL / Neonate: 2-300 mL (increments of 1 mL)

f (Ventilation frequency): 1-80 bpm / Neonate: 1-150 bpm (increments of 1 bpm) fSIMV (Ventilation frequency in SIMV mode): 1-80 bpm / Neonate: 1-150 bpm (increments of 1 bpm)

I:E range: 4:1-1:10 (increments of 0.5)

Tinsp (Inspiratory time): 0.20-10 s (increments of 0.05 s)

Tslope (Time of Pressure Rising): 0-2.00 s (increments of 0.05 s)

Thigh: 0.2-30 s (increments of 0.1 s)

Tlow: 0.2-30 s (increments of 0.1 s)

Tpause: 5%-60% (increments of 1%), Off)

ΔPinsp: 5-60 cm H2O (increments of 1 cm H2O)

ΔPsupp: 0-60 cm H2O (increments of 1 cm H2O)

Phigh: 0-60 cm H2O (increments of 1 cm H2O)

Plow: 0-45 cm H2O (increments of 1 cm H2O)

PEEP: 1-45 cm H2O (increments of 1 cm H2O), Off)

Flow trigger: 0.5-15 L/min (increments of 0.1 L/min)

Pressure trigger: -10 to -0.5 cm H2O (increments of 0.5 cm H2O)

Exp% (Expiration termination level): 10-85% (increments of 5%), Auto

Technical Specifications

Apnea Ventilation

Vtapnea: Adult: 100-2000 mL (increments of 10 mL) / Pediatric: 20-300 mL /Neonate: 2-300 mL (increments of 1 mL) ΔPapnea: 5-60 cm H2O (increments of 1 cm H2O) Fapnea: 1-80 bpm (increments of 1 bpm) Apnea Tinsp: 0.20-10 s (increments of 0.05 s)

Sigh

Sigh Switch: On, Off

Interval: 20 s-180 min (increments of 1 s from 20 to 59 s, increments of 1 min from 1 to 180 min)

Cycles Sigh: 1-20 (increments of 1)

Δint.PEEP: 1-45 cm H2O (increments of 1 cm H2O), Off

Synchronized Tube Resistance Compliance Tube

Type: ET Tube, Trach Tube, Disable STRC Tube

I.D.: Adult: 5.0 -12.0 mm (increments of 0.5 mm) / Pediatric: 2.5 - 8.0 mm increments of 0.5 mm)

Compensate: 0-100% (increments of 1%)

Expiration Compliance Switch: On, Off

Monitored parameters

Numeric:

​

​

Real time Graphics:

Pressure-time waveforms: Paw-Volume Loop

Flow-time waveforms: Flow-time Loop Volumetime waveforms: Paw-Flow Loop

Control Accuracy

O2%: ±(3 vol.% +1% of setting)

TV: ±(10 mL +10% of setting) (BTPS)

Tinsp: ±0.1 s or ±10% of setting, whichever is greater

I: E 2:1 to 1:4: ±10% of setting, other range: ±15% of setting

f: ±1 bpm

fSIMV: ±1 bpm

Tslope: ±(0.2 s + 20% of setting)

PEEP: ±(2.0 cm H2O + 5% of setting) ΔPinsp: ±(2.0 cm H2O + 5% of setting) ΔPsupp: ±(2.0 cm H2O + 5% of setting) Phigh: ±(2.0 cm H2O + 5% of setting)

Plow: ±(2.0 cm H2O + 5% of setting)

Thigh: ±0.2 s or ±10% of setting, whichever is greater

Tlow: ±0.2 s or ±10% of setting, whichever is greater

Pressure Trigger: ±(1.0 cm H2O + 10% of setting)

Flow Trigger: ±(1.0 L/min + 10% of setting)

Δint.PEEP: ±(2.0 cm H2O + 5% of setting) Exp%: ±10%

fapnea: ±1 bpm

ΔPapnea: ±(2.0 cm H2O + 5% of setting) Tvapnea: ±(10 mL + 10% of setting) (BTPS) Apnea Tinsp: ±0.1 s or ±10% of setting, whichever is greater

 

Monitoring Accuracy

Airway pressure (Ppeak, Pplat, Pmean, PEEP, PAP, EPAP): ±(2 cm H2O + 4% of the actual reading)

Tidal Volume: (Tvi, Tve, TVe/IBW, TVe spn): 0 ml-100 ml: ±(10 ml + 3% of the actual reading) (BTPS) 100 ml-4000 ml: ±(3 ml +10% of the actual reading) (BTPS)

Minute Volume (MV, MVspn, Mvleak): ±0.3 L/min or ±8% of the actual reading, whichever is greater (BTPS)

Frequency (ftotal, fmand, fspn): ±5% of reading or ±1bpm, whichever is greater

Inspired Oxygen (FiO2): ±(2.5 vol.% + 2.5% of the actual reading)

Resistance: 0 to 50: ±10 cm H2O/L/s

Other range: 50% of the actual reading

Compliance: 25% of the actual reading or ±10 ml/cm H2O, whichever is greater

RSBI: 0 to 999 1/(min*L): ± (3 1/(min*L) ± 15% of the actual reading)

WOB: -

NIF: ±(2 cm H2O + 4% of the actual reading) P0.1:

±(2 cm H2O + 4% of the actual reading) PEEPi: - Rcexp: -

 

Alarm settings

Tidal Volume: High / Low

Minute Volume: High / Low

Airway pressure: High / Low

Frequency: High / Low

Inspired Oxygen (FiO2): High / Low

etCO2: High / Low

Apnea alarm time: 5-60 s

 

Trend

Type: Tabular, Graphic

Length: 72 hours

Content: Monitor Parameters, Setting Parameters (Setting Ventilation mode and Parameters)

 

Technical Specifications

Controlled Parameters

O2%: 21-100% (increments of 1%)

Flow: 4-60 L/min

Controlled Accuracy

O2%: ±(3 vol.% +1% of setting)

Flow: ±(2 L/min +10% of setting) (BTPS)

Environmental specifications

Temperature: 5-40 °C (operating); -20 to 60 °C (storage and transport, O2sensor: -20 to 50°C)

Relative Humidity: 10-95% (operating); 10-95% (storage and transport)

Barometric Pressure: 62-106 kPa (operating); 50-106 kPa (storage and transport)

Power Battery Backup

External AC power supply

Input voltage: 100-240 V

Input frequency: 50/60 Hz

Input current: 2.5 A Max

Fuse: T2.5 AH/250 V

Internal battery

Number of batteries: One or Two (Optional)

Battery type: Build-in Lithium-ion battery, 11.25 VDC, 6400 mAh

Battery run time: 3 hours (Powered by one new fully-charged battery in standard working condition), 6 hours (powered by two new fully-charged batteries in standard working condition).

Others

Communication interface: RS-232, Ethernet, USB port, CO2 analyzer connector

Gas supply: O2 (HPO) Oxygen connector: NIST (DISS optional)

Gas supply pressure: 280-600 kPa